Qlogic Fibre Channel NPIV Storage Networking Guide Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Redes Qlogic Fibre Channel NPIV Storage Networking Guide. Qlogic Fibre Channel NPIV Storage Networking Guide User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
FC0054607-00 A
Fibre Channel and Converged Network
Adapters for VMware ESX/ESXi 4.0
Users Guide
Vista de página 0
1 2 3 4 5 6 ... 61 62

Resumo do Conteúdo

Página 1 - User’s Guide

FC0054607-00 AFibre Channel and Converged NetworkAdapters for VMware ESX/ESXi 4.0User’s Guide

Página 2 - Document Revision History

x FC0054607-00 A Text within square brackets indicates optional parameters. For exampleiscli [optional parameters] [Command Variable] Tex t i n b

Página 3 - Table of Contents

FC0054607-00 A xiVisit the QLogic support Web site listed in Contact Information for the latest firmware and software updates.AvailabilityQLogic Tech

Página 4 - List of Tables

xii FC0054607-00 ANotes

Página 5 - FC0054607-00 A v

FC0054607-00 A 1-11 Hardware and Software ComponentsThis chapter provides details about QLogic Fibre Channel and Converged Network Adapters in VMware

Página 6

1–Hardware and Software ComponentsHardware Components1-2 FC0054607-00 AFigure 1-1 Adapter ComponentsTable 1-1. Adapter Component DetailsCallout Numb

Página 7 - Preface

1–Hardware and Software ComponentsSoftware ComponentsFC0054607-00 A 1-3Software ComponentsThis section describes the following QLogic adapter softwar

Página 8 - What’s in This Guide

1–Hardware and Software ComponentsSupported QLogic Adapters1-4 FC0054607-00 AFirmwareThe firmware module performs most of the Fibre Channel and FCoE

Página 9 - Documentation Conventions

FC0054607-00 A 2-12 InstallationThis chapter provides the following installation information: Supported Features “Installing the Hardware” on page

Página 10 - Technical Support

2–InstallationInstalling the Hardware2-2 FC0054607-00 A Support for MSI-X—on 4/8Gb Fibre Channel and Converged Network Adapters. Support for VMware

Página 11 - Knowledge Database

2–InstallationInstalling the DriverFC0054607-00 A 2-35. Refasten the adapter's retaining bracket using the existing screw or lever.6. Close the

Página 12

ii FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideInformation furnished in this manual is believed t

Página 13 - 1 Hardware and Software

2–InstallationInstalling SANsurfer Management Tools2-4 FC0054607-00 AInstalling SANsurfer FC HBA ManagerTo run SANsurfer FC HBA Manager on a VMware E

Página 14 - Callout

2–InstallationInstalling SANsurfer Management ToolsFC0054607-00 A 2-52. Click the by Operating System button, and then select Fibre Channel Adapters,

Página 15 - Software Components

2–InstallationInstalling SANsurfer Management Tools2-6 FC0054607-00 Ac. In the command window, type hostname, and then press ENTER.9. On the ESX Host

Página 16 - Supported QLogic Adapters

2–InstallationInstalling SANsurfer Management ToolsFC0054607-00 A 2-73. Click Go.4. Under Management Tools, click SANsurfer FC HBA Manager (x86/x64).

Página 17 - 2 Installation

2–InstallationInstalling SANsurfer Management Tools2-8 FC0054607-00 A4. On the VMware ESX/ESXi download page under Management Tools, click SANsurfer

Página 18 - Installing the Hardware

FC0054607-00 A 3-13 ConfigurationQLogic Fibre Channel and Converged Network Adapters on VMware ESX/ESXi 4.0 configuration procedures include the foll

Página 19 - Installing the Driver

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.03-2 FC0054607-00 ATo identify QLogic Fibre Channel and Converged Network Adapters us

Página 20

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.0FC0054607-00 A 3-3To identify QLogic Fibre Channel and Converged Network Adapters us

Página 21 - $ hostname

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.03-4 FC0054607-00 AFigure 3-2 Finding Adapters on VMware ESX/ESXi 4.0Driver informat

Página 22 - 2-6 FC0054607-00 A

3–ConfigurationUsing the QLogic Fast!UTIL BIOS UtilityFC0054607-00 A 3-5 NPIV Supported indicates whether the adapter port supports NPIV. If Yes, th

Página 23 - FC0054607-00 A 2-7

FC0054607-00 A iiiTable of ContentsPrefaceIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Página 24

3–ConfigurationVerifying That the Driver is Loaded3-6 FC0054607-00 A Select Host Adapter setting enables you to select a specific adapter, if you ha

Página 25 - 3 Configuration

3–ConfigurationConfiguring the Driver ParametersFC0054607-00 A 3-7Figure 3-3 Verifying That the Driver is LoadedConfiguring the Driver ParametersUse

Página 26 - Using Console OS

3–ConfigurationConfiguring the Driver Parameters3-8 FC0054607-00 Awhere <options> is one of the configurable parameters listed in Table 3-1 on

Página 27

3–ConfigurationDeploying NPIV for VMware ESX/ESXi 4.0FC0054607-00 A 3-9Deploying NPIV for VMware ESX/ESXi 4.0QLogic Fibre Channel and Converged Netwo

Página 28 - 3-4 FC0054607-00 A

3–ConfigurationMonitoring NPIV Virtual Ports from SANsurfer3-10 FC0054607-00 AVMware ESX/ESXi 4.0 enables NPIV support on QLogic 4Gb/8Gb Fibre Channe

Página 29 - FC0054607-00 A 3-5

3–ConfigurationMonitoring NPIV Virtual Ports from SANsurferFC0054607-00 A 3-11Figure 3-4 SANsurfer FC HBA Manager Showing NPIVWhen you select an ind

Página 30 - $ vmkload_mod -l

3–ConfigurationConfiguring Boot from SAN3-12 FC0054607-00 AFigure 3-5 Virtual Port Information Page in SANsurferConfiguring Boot from SANBoot from S

Página 31 - # esxcfg-module -g qla2xxx

3–ConfigurationConfiguring Boot from SANFC0054607-00 A 3-13VMware ESX/ESXi 4.0 provides boot from SAN capability on QLogic Fibre Channel Adapters. Fo

Página 32

3–ConfigurationConfiguring Boot from SAN3-14 FC0054607-00 A7. After the Host Adapter BIOS is enabled, select the boot device as shown in the followin

Página 33 - Table Footnotes

FC0054607-00 A A-1A TroubleshootingThis appendix provides the following methods of determining the status of the adapters and finding solutions to co

Página 34 - 3-10 FC0054607-00 A

iv FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideUsing the QLogic Fast!UTIL BIOS Utility . . . . .

Página 35 - FC0054607-00 A 3-11

A–TroubleshootingTroubleshooting with LEDsA-2 FC0054607-00 ATable A-2. QLA24xx/QLE24xx/QEM2462 Adapter LED SchemeYellow LED Green LED Amber LED Activ

Página 36 - Configuring Boot from SAN

A–TroubleshootingDynamic Extended LoggingFC0054607-00 A A-3 Dynamic Extended LoggingThe QLogic driver provides a mechanism to dynamically enable exte

Página 37 - FC0054607-00 A 3-13

A–TroubleshootingTroubleshooting with Driver LogsA-4 FC0054607-00 AWhen the logging is enabled, the driver version in the /proc/scsi/qla2xxx/<adap

Página 38

A–TroubleshootingTroubleshooting with Driver LogsFC0054607-00 A A-5Aug 18 15:15:13 localhost vmkernel: 0:00:00:34.550 cpu6:4109)<6>qla2xxx 0000

Página 39 - A Troubleshooting

A–TroubleshootingTroubleshooting with Driver LogsA-6 FC0054607-00 ATable A-6 lists the more common driver log messages and provides an explanation of

Página 40

A–TroubleshootingTroubleshooting with Driver LogsFC0054607-00 A A-7"scsi(%d): RSCN,..."Driver received a registered state change notificati

Página 41 - Dynamic Extended Logging

A–TroubleshootingTroubleshooting with Driver LogsA-8 FC0054607-00 A"WARNING qla2xxx: Couldn't allocate host from scsi layer!"Indicates

Página 42

A–TroubleshootingDebugging Using Proc InformationFC0054607-00 A A-9Debugging Using Proc InformationThe driver /proc/scsi/qla2xxx/<adapter_number&g

Página 43

A–TroubleshootingCollecting System Logs for TroubleshootingA-10 FC0054607-00 ACollecting System Logs for TroubleshootingTo collect all relevant data

Página 44

FC0054607-00 A Glossary-1GlossaryadapterThe board that interfaces between the host system and the target devices. Adapter is synonymous with host bus

Página 45

FC0054607-00 A vFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuideA-6 Common Driver Log Messages . . . . . . . . . . .

Página 46

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-2 FC0054607-00 AcacheA temporary high-speed storage (memo

Página 47

FC0054607-00 A Glossary-3Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guidefabric switchAlso, switched fabric. Connect

Página 48 - Frequently Seen Issues

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-4 FC0054607-00 AISLInter-switch link. The connection betw

Página 49

FC0054607-00 A Glossary-5Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuideN_PortNode port. A port that connects by a

Página 50 - Glossary-2 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-6 FC0054607-00 AThis is important to the driver when sele

Página 51 - FC0054607-00 A Glossary-3

FC0054607-00 A Glossary-7Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuidetargetThe storage-device endpoint of a SCSI

Página 52 - Glossary-4 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-8 FC0054607-00 ANotes

Página 53 - FC0054607-00 A Glossary-5

FC0054607-00 A Index-1IndexAacronyms, definitions of Glossary-1adapter port beacon, definition of Glossary-1adapter port, definition of Glossary-1

Página 54 - Glossary-6 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideIndex-2 FC0054607-00 Adeviceboot, configuring 3-5definition of G

Página 55 - FC0054607-00 A Glossary-7

FC0054607-00 A Index-3Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guideinstalling 2-1driver 2-3hardware 2-2SANsurf

Página 56 - Glossary-8 FC0054607-00 A

vi FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideNotes

Página 57 - FC0054607-00 A Index-1

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideIndex-4 FC0054607-00 ANPIVdefinition of Glossary-5deploying 3-9v

Página 58 - Index-2 FC0054607-00 A

FC0054607-00 A Index-5Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guidesupportedadapters 1-4features 2-1system logs

Página 59 - FC0054607-00 A Index-3

© 2009 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic and the QLogic logo are register

Página 60 - Index-4 FC0054607-00 A

FC0054607-00 A viiPreface QLogic provides a portfolio of Fibre Channel Adapters, Intelligent Ethernet Adapters, and Converged Network Adapters on the

Página 61 - FC0054607-00 A Index-5

viii FC0054607-00 A SANsurfer FC HBA CLI User’s Guide (part number SN0054614-00) SANsurfer FC HBA CLI release notes and ReadMe fileRelated VMware d

Página 62

FC0054607-00 A ix 2 Installation details the supported features and covers installation of hardware, drivers, and SANsurfer® management tools. 3 Co

Comentários a estes Manuais

Sem comentários