Qlogic SANsurfer FC HBA Manager Guia do Utilizador Página 163

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 218
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 162
10 – Performing Diagnostics
Viewing the Diagnostic Test Results
FS0054603-00 C 10-11
Q
10.4.2
Read/Write Buffer Test Results
The Read/Write Buffer Test Results section provides the following information, as
shown in figure 10-4.
Figure 10-4. Diagnostic Test ResultsRead/Write Buffer Test
Loop ID/Status
The loop ID of the HBA when operating in loop mode.
The status of the testwhether the test passed or failed. The possible values:
Success. The test passed.
Error. A data miscompare or link status firmware error occurred.
Failed. A link status error, SCSI write buffer error, or SCSI read buffer error
occurred.
Unknown. The target was not present.
Unsupported. The device does not support this test.
Data Miscompare. The possible values:
0 (no data miscompares)
Device not present
Get link status failed
Read buffer failed
Vista de página 162
1 2 ... 158 159 160 161 162 163 164 165 166 167 168 ... 217 218

Comentários a estes Manuais

Sem comentários