IS0053302-00 7 PRELIMINARY Page i
Q
Simplify
QLA4010/4010C Users Guide
1-Gb iSCSI to PCI-X Host Bus Adapters
Vista de página 0
1 2 3 4 5 6 ... 81 82

Resumo do Conteúdo

Página 1 - QLA4010/4010C User’s Guide

IS0053302-00 7 PRELIMINARY Page iQSimplifyQLA4010/4010C User’s Guide1-Gb iSCSI to PCI-X Host Bus Adapters

Página 2

1 – IntroductionTechnical Support1-4 PRELIMINARY IS0053302-00 7QNotes

Página 3 - Table of Contents

IS0053302-00 7 PRELIMINARY I-1Part I HardwareThis part of the QLA4010/4010C User’s Guide describes the host bus adapters (HBAs) and how to insta

Página 4 - Part III Applications

I – HardwareI-2 PRELIMINARY IS0053302-00 7QNotes

Página 5 - Figure Page

IS0053302-00 7 PRELIMINARY 2-1Section 2 QLA4010/4010C2.1Installation in the ComputerBefore you install the QLA4010/4010C HBA in your computer, y

Página 6 - Table Page

2 – QLA4010/4010CInstallation in the Computer2-2 PRELIMINARY IS0053302-00 7QNOTE: Some motherboards have two kinds of PCI bus slots: master and slave

Página 7

2 – QLA4010/4010CAgency CertificationIS0053302-00 7 PRELIMINARY 2-3Q2.2SpecificationsTables 2-1 and 2-2 define the QLA4010/4010C HBA specifications.

Página 8 - Training

2 – QLA4010/4010CAgency Certification2-4 PRELIMINARY IS0053302-00 7QNotes

Página 9 - Contact Information

IS0053302-00 7 PRELIMINARY II-1Part II SoftwareThis part of the QLA4010/4010C User’s Guide describes how to install the software drivers for the

Página 10 - Technical Support

II – SoftwareII-2 PRELIMINARY IS0053302-00 7QNotes

Página 11 - Hardware

IS0053302-00 7 PRELIMINARY 3-1Section 3 Windows 2000 Driver Installation(QL4010.SYS)3.1Supported Features The Windows 2000 driver (QL4010.sys)

Página 12 - I – Hardware

QLA4010/4010C User’s Guide1-Gb iSCSI to PCI-X Host Bus AdaptersQPage ii PRELIMINARY IS0053302-00 7Information furnished in this manual is believed to

Página 13 - QLA4010/4010C

3 – Windows 2000 Driver InstallationInstalling the Driver3-2 PRELIMINARY IS0053302-00 7Qb. To download the driver from the QLogic web site, follow th

Página 14 - Installation in the Computer

3 – Windows 2000 Driver InstallationInstalling the DriverIS0053302-00 7 PRELIMINARY 3-3QAfter all the standard devices have been loaded, press S to S

Página 15 - Specifications

3 – Windows 2000 Driver InstallationInstalling the Driver3-4 PRELIMINARY IS0053302-00 7Q11. Windows 2000 displays the Found New Hardware—Network Cont

Página 16

3 – Windows 2000 Driver InstallationRemoving the DriverIS0053302-00 7 PRELIMINARY 3-5Q5. In the Install Hardware Device Drivers dialog box, select Di

Página 17 - Software

3 – Windows 2000 Driver InstallationRemoving the Driver3-6 PRELIMINARY IS0053302-00 7QNotes

Página 18 - II – Software

IS0053302-00 7 PRELIMINARY 4-1Section 4 Windows Server 2003 Driver Installation(QL4010.SYS)4.1Supported Features The Windows Server  2003 drive

Página 19 - (QL4010.SYS)

4 – Windows Server 2003 Driver InstallationInstalling the Driver4-2 PRELIMINARY IS0053302-00 7Qb. To download the driver from the QLogic web site, fo

Página 20 - Installing the Driver

4 – Windows Server 2003 Driver InstallationInstalling the DriverIS0053302-00 7 PRELIMINARY 4-3QAfter all the standard devices have been loaded, press

Página 21

4 – Windows Server 2003 Driver InstallationInstalling the Driver4-4 PRELIMINARY IS0053302-00 7Q11. Select Search for the best driver in these locatio

Página 22 - Updating the Existing Driver

4 – Windows Server 2003 Driver InstallationRemoving the DriverIS0053302-00 7 PRELIMINARY 4-5Q4.5Removing the DriverTo uninstall the QLA4010.SYS drive

Página 23 - Removing the Driver

IS0053302-00 7 PRELIMINARY Page iiiTable of ContentsSection 1 Introduction1.1 How to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . .

Página 24

4 – Windows Server 2003 Driver InstallationRemoving the Driver4-6 PRELIMINARY IS0053302-00 7QNotes

Página 25

IS0053302-00 7 PRELIMINARY 5-1Section 5 Red Hat Linux Driver Installation5.1IntroductionThis section provides instructions for installing the Re

Página 26

5 – Red Hat Linux Driver InstallationInstalling the Driver5-2 PRELIMINARY IS0053302-00 7Q5.3.1Building a Uniprocessor (UP) Version of the DriverPerfo

Página 27

5 – Red Hat Linux Driver InstallationInstalling the DriverIS0053302-00 7 PRELIMINARY 5-3Q5.3.2Building a Symmetric Multiprocessor (SMP) Version of th

Página 28

5 – Red Hat Linux Driver InstallationInstalling the Driver5-4 PRELIMINARY IS0053302-00 7Q5. Create a new directory, /qla4xxx. Using the driver disk c

Página 29

5 – Red Hat Linux Driver InstallationInstalling the DriverIS0053302-00 7 PRELIMINARY 5-5QBefore building a RAMDISK image, you must build a UP or SMP

Página 30

5 – Red Hat Linux Driver InstallationInstalling the Driver5-6 PRELIMINARY IS0053302-00 7Q5.3.5Building a Custom Kernel with the QLogic DriverShould t

Página 31 - Introduction

5 – Red Hat Linux Driver InstallationInstalling the DriverIS0053302-00 7 PRELIMINARY 5-7Qa. For Red Hat Advanced Server 2.1, locate the following lin

Página 32

5 – Red Hat Linux Driver InstallationInstalling the Driver5-8 PRELIMINARY IS0053302-00 7Q4. Configure the kernel to load the QLogic driver by typing:

Página 33

5 – Red Hat Linux Driver InstallationSystem Driver Parameter max_scsi_lunsIS0053302-00 7 PRELIMINARY 5-9Qd. Restart the system. The new kernel image

Página 34 - Loading the Driver Manually

QLA4010/4010C User’s Guide1-Gb iSCSI to PCI-X Host Bus AdaptersPage iv PRELIMINARY IS0053302-00 7Q4.4.2 Adding the QLA4010/4010C HBA to the Existing

Página 35

5 – Red Hat Linux Driver InstallationDriver Command Line Parameters5-10 PRELIMINARY IS0053302-00 7Q2. Run LILO by typing the following:#/sbin/lilo3.

Página 36 - Prerequisites

IS0053302-00 7 PRELIMINARY III-1Part III ApplicationsThis part of the QLA4010/4010C User’s Guide describes the SANsurfer Control iX GUI, a stand

Página 37

III – ApplicationsIII-2 PRELIMINARY IS0053302-00 7QNotes

Página 38

IS0053302-00 7 PRELIMINARY 6-1Section 6 SANsurfer Control iX6.1IntroductionThe QLA4010/4010C HBA includes the SANsurfer Control iX GUI. The SANs

Página 39

6 – SANsurfer Control iXInstalling SANsurfer Control iX6-2 PRELIMINARY IS0053302-00 7Q❑For a Red Hat Linux system, do the following:(1) Open a shell.

Página 40 - Proc Filesystem Support

6 – SANsurfer Control iXInstalling SANsurfer Control iXIS0053302-00 7 PRELIMINARY 6-3QFigure 6-2. Choose Install Folder Dialog Box5. The Choose Short

Página 41 - Applications

6 – SANsurfer Control iXInstalling SANsurfer Control iX6-4 PRELIMINARY IS0053302-00 7Q6. If you are installing the SANsurfer Control iX GUI on a Wind

Página 42 - III – Applications

6 – SANsurfer Control iXInstalling SANsurfer Control iXIS0053302-00 7 PRELIMINARY 6-5Q8. The Install Complete dialog box displays (see figure 6-6). C

Página 43 - SANsurfer Control iX

6 – SANsurfer Control iXGetting Started6-6 PRELIMINARY IS0053302-00 7Q6.3Getting StartedThis section includes the procedures for starting the SANsurf

Página 44 - /install.bin

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-7Q6.3.1.2Starting SANsurfer Control iX on Red Hat LinuxOn a Red Hat Linux system,

Página 45

QLA4010/4010C User’s GuideIS0053302-00 7 PRELIMINARY Page vQQLA4010/4010C User’s Guide1-Gb iSCSI to PCI-X Host Bus Adapters6.3.3 Exiting the SANsurfe

Página 46

6 – SANsurfer Control iXGetting Started6-8 PRELIMINARY IS0053302-00 7QWhen SANsurfer Control iX starts, the first screen is the main window, which de

Página 47 - Red Hat Linux

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-9QThe menu bar has three options: File❑Exit. Select this option to exit SANsurfer

Página 48 - Starting SANsurfer Control iX

6 – SANsurfer Control iXGetting Started6-10 PRELIMINARY IS0053302-00 7QTo view target information, click the target in the HBA tree. The Target Infor

Página 49

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-11QTo view LUN information, click the LUN in the HBA tree, or click the LUN List

Página 50

6 – SANsurfer Control iXGetting Started6-12 PRELIMINARY IS0053302-00 7Q6.3.2.1Host Tabbed PageWhen SANsurfer Control iX starts, the first screen is t

Página 51

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-13Q6.3.2.2HBA Tabbed PagesUse the HBA Options tabbed page first to set basic QLA4

Página 52

6 – SANsurfer Control iXGetting Started6-14 PRELIMINARY IS0053302-00 7QFigure 6-13. HBA Options Tabbed Page (Network)6.3.2.3Target Settings Tabbed Pa

Página 53

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-15Q6.3.2.4Target Information Tabbed PageThe Target Information tabbed page provid

Página 54 - Host Tabbed Page

6 – SANsurfer Control iXGetting Started6-16 PRELIMINARY IS0053302-00 7Q6.3.2.5HBA Information Tabbed PageThe HBA Information tabbed page is for infor

Página 55 - HBA Tabbed Pages

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-17Q6.3.2.6Statistics Tabbed PageThe Statistics tabbed page contains information a

Página 56 - Target Settings Tabbed Page

QLA4010/4010C User’s Guide1-Gb iSCSI to PCI-X Host Bus AdaptersPage vi PRELIMINARY IS0053302-00 7Q6-8 Host Information Tabbed Page (Main Window) . .

Página 57

6 – SANsurfer Control iXGetting Started6-18 PRELIMINARY IS0053302-00 7Q6.3.2.7Diagnostics Tabbed PageThe diagnostics tabbed page allows you to ping a

Página 58 - HBA Information Tabbed Page

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-19Q6.3.3Exiting the SANsurfer Control iX GUIDo one of the following to exit the S

Página 59 - Statistics Tabbed Page

6 – SANsurfer Control iXGetting Started6-20 PRELIMINARY IS0053302-00 7QIf you do not know the location, click Browse to display a file selection dial

Página 60 - Diagnostics Tabbed Page

6 – SANsurfer Control iXGetting StartedIS0053302-00 7 PRELIMINARY 6-21QNOTE: The default SANsurfer Control iX application access password is config.

Página 61 - Viewing Online Help

6 – SANsurfer Control iXConfiguring the QLA4010/4010C HBA6-22 PRELIMINARY IS0053302-00 7Q6.4Configuring the QLA4010/4010C HBAThe following sections p

Página 62

6 – SANsurfer Control iXConfiguring the QLA4010/4010C HBAIS0053302-00 7 PRELIMINARY 6-23Q3. Configure the HBA as described in the following sections.

Página 63

6 – SANsurfer Control iXConfiguring the QLA4010/4010C HBA6-24 PRELIMINARY IS0053302-00 7QTo set the DNS server address automatically through DHCP, se

Página 64

6 – SANsurfer Control iXConfiguring TargetsIS0053302-00 7 PRELIMINARY 6-25Q6.5Configuring TargetsAfter configuring the QLA4010/4010C HBA, you can ent

Página 65 - Setting the IP Address

6 – SANsurfer Control iXConfiguring Targets6-26 PRELIMINARY IS0053302-00 7Qf. Selects the Bind check box is if the Auto-bind Discovered Targets check

Página 66 - Enabling iSNS

6 – SANsurfer Control iXConfiguring TargetsIS0053302-00 7 PRELIMINARY 6-27QCAUTION!The iSCSI port number defaults to 3260. Do not change this number

Página 67 - Configuring Using Discovery

IS0053302-00 7 PRELIMINARY 1-1Section 1 Introduction1.1How to Use this GuideThe SANblade™ QLogic host bus adapters (HBAs) supported in this doc

Página 68

6 – SANsurfer Control iXConfiguring Targets6-28 PRELIMINARY IS0053302-00 7Q11. QLogic recommends restarting the host PC for the operating system to r

Página 69 - Configuring Specific Targets

6 – SANsurfer Control iXConfiguring TargetsIS0053302-00 7 PRELIMINARY 6-29Q❑Enable. When the check box is selected in this read-only field, the targe

Página 70

6 – SANsurfer Control iXConfiguring Targets6-30 PRELIMINARY IS0053302-00 7Q4. At the prompt, enter your password. The CHAP tabbed page displays (see

Página 71 - Authenticating Targets (CHAP)

6 – SANsurfer Control iXConfiguring the FirmwareIS0053302-00 7 PRELIMINARY 6-31Q8. If the enabled targets are configured to use the same initiator na

Página 72

6 – SANsurfer Control iXConfiguring the Firmware6-32 PRELIMINARY IS0053302-00 7Q3. Next to the phrase Configured Firmware Values, click Open. A read-

Página 73 - Configuring the Firmware

6 – SANsurfer Control iXConfiguring the FirmwareIS0053302-00 7 PRELIMINARY 6-33Qparameter column. When you are done changing the parameters, click OK

Página 74

6 – SANsurfer Control iXConfiguring the Firmware6-34 PRELIMINARY IS0053302-00 7Q❑MaxBurstLength. This column indicates the maximum length for data se

Página 75

6 – SANsurfer Control iXConfiguring the FirmwareIS0053302-00 7 PRELIMINARY 6-35Q❑Ethernet Pause. When this check box is selected, the QLA4010/4010C H

Página 76

6 – SANsurfer Control iXConfiguring the Firmware6-36 PRELIMINARY IS0053302-00 7Q6.6.2Restoring the Factory DefaultsPerform the following steps to res

Página 77

6 – SANsurfer Control iXConfiguring the FirmwareIS0053302-00 7 PRELIMINARY 6-37Q9. The Firmware Download Warnings dialog box displays (see figure 6-2

Página 78 - Firmware Upgrade

1 – IntroductionFeatures1-2 PRELIMINARY IS0053302-00 7Q1.3Features Compliance with PCI Local Bus Specification revision 2.2 and PCI-X Specification r

Página 79

6 – SANsurfer Control iXConfiguring the Firmware6-38 PRELIMINARY IS0053302-00 7Q13. The Open dialog box displays. Select the firmware file (downloade

Página 80 - Viewing the HBA Crash Record

6 – SANsurfer Control iXPerforming DiagnosticsIS0053302-00 7 PRELIMINARY 6-39Q3. The Save Crash Record dialog box displays (see figure 6-33). Figure

Página 81 - Pinging a Target

6 – SANsurfer Control iXPerforming Diagnostics6-40 PRELIMINARY IS0053302-00 7Q6.7.2Viewing the ARP and Connection Error TablesPerform the following s

Página 82

1 – IntroductionTechnical SupportIS0053302-00 7 PRELIMINARY 1-3Q1.4.3Contact InformationAddress: QLogic Corporation6321 Bury DriveEden Prairie, Minne

Comentários a estes Manuais