A Specifications
Switch Dimensions
59042-01 A A-3
A.4
Switch Dimensions
A.5
Switch Electrical
A.6
Switch Environmental
Width...............................................
Height .............................................
Depth ..............................................
8.5
1.70
20.0
Weight............................................. 8.5 lbs.
Operating voltage ........................... 90 to 137 Vac; 47 to 63 Hz
180 to 264 Vac; 47 to 63 Hz
Power source loading..................... 1.0 Amps maximum at 90 to 137 Vac
0.45 Amps maximum at 180 to 264 Vac
Heat Output (maximum) 70 watts
Circuit Protection ............................ Internally fused
Temperature
Operating..................................
Non-operating...........................
5 to 50°C (41 to 122°F)
-40 to 65°C (-40 to 149°F)
Humidity
Operating..................................
Non-operating...........................
15% to 80%, non-condensing
25% to 90%, non-condensing
Altitude
Operating..................................
Non-operating...........................
0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
Vibration
Operating..................................
Non-operating...........................
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
Shock
Operating..................................
Non-operating...........................
IEC 68-2
4 g, 11ms, 20 repetitions
30g, 292 ips, 3 repetitions, 3 axis
Air flow............................................ Front-to-back or back-to-front, by model